Altigen ACM 6.5 Guide de l'utilisateur Page 391

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 502
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 390
MAXCS ACM 6.5 Administration Manual 377
C
HAPTER
26
Redundancy Configuration
MAX Communication Server 6.5 provides for system redundancy (a Redundancy license
is required). Two Softswitch servers, primary and secondary, must be set up and
connected through a Dataprobe A\B switch box (KAB). The two servers maintain a keep-
alive connection between them directly, MAXCS to MAXCS. When the active server goes
down, the standby server takes over control. The change is transparent to direct
connected calls. (See “How Calls Are Affected When Switchover Occurs” on page 379.)
The primary and secondary servers must be located in the same LAN, and they must
share the same public IP addresses, so that external services and applications can
connect, no matter which server is handling the traffic.
The minimum configuration for system redundancy consists of the primary Softswitch,
the secondary Softswitch, gateways, Voice Mail server, External Logger, and CDR
database systems. See Figure 1, “Redundancy topology".
Vue de la page 390
1 2 ... 386 387 388 389 390 391 392 393 394 395 396 ... 501 502

Commentaires sur ces manuels

Pas de commentaire